Marine, pétrole, gaz et pétrochimie Câbles |
|
|
British Standard Shipwiring cables to BS 6883
Flexible armoured screened Instrument cables
Manufactured in both pairs and triples these 150/250V instrumentation cables provide collective or individual screening through the use of metallic foils and drain wires. Offering good flexibility for installation in confined spaces or where difficult routing is necessary, the galvanised steel wire braid provides mechanical protection |
Core Identification
Pairs : |
Each pair black, white and numbered |
Triples : |
Each triple black, white, red and numbered |
Alternative colour codes are available |
Information technique
Tension nominale |
150/250V |
Conductors |
Tinned, BS6360 class 2 or class 5 |
Température avis |
+90°C maximum conductor temperature |
Static temperature rating |
-30°C to +90°C |
Bending radius (static) |
8 x cable O/D |
Retardateur de flamme |
IEC60332 part 3A, BS4066 part 3A |
Données techniques
Nombre de paires |
Nominal Conductor
Cross-Sectional
Area mm² |
Diameter over
inner sheath
min-max mm |
Diamètre de gaine
min-max mm |
Pairs collective
|
3 |
0.75 |
12.6 - 14.5 |
16.7 - 19.0 |
7 |
0.75 |
16.6 - 18.7 |
20.9 - 23.8 |
12 |
0.75 |
21.7 - 24.2 |
26.4 - 29.5 |
20 |
0.75 |
27.3 - 30.1 |
33.3 - 37.1 |
27 |
0.75 |
31.1 - 34.2 |
37.4 - 41.4 |
37 |
0.75 |
34.4 - 37.7 |
41.0 - 45.0 |
3 |
1 |
13.3 - 15.3 |
17.4 - 19.8 |
7 |
1 |
17.6 - 19.8 |
22.1 - 25.1 |
12 |
1 |
23.1 - 25.7 |
28.0 - 31.2 |
20 |
1 |
29.1 - 31.9 |
35.3 - 39.2 |
27 |
1 |
33.3 - 36.6 |
39.7 - 44.2 |
37 |
1 |
36.9 - 40.3 |
43.7 - 48.3 |
Pairs individual
|
1 |
0.75 |
7.3 - 9.0 |
11.1 - 12.9 |
3 |
0.75 |
12.6 - 14.5 |
16.7 - 19.0 |
7 |
0.75 |
16.9 - 19.0 |
21.4 -24.3 |
12 |
0.75 |
21.3 - 23.7 |
26.1 - 29.2 |
20 |
0.75 |
27.0 - 29.8 |
33.2 - 37.0 |
27 |
0.75 |
30.8 - 33.9 |
37.3 - 41.3 |
37 |
0.75 |
25.9 - 39.3 |
42.9 - 47.5 |
1 |
1 |
7.7 - 9.5 |
11.5 - 13.4 |
3 |
1 |
13.5 - 15.5 |
17.6 - 20.0 |
7 |
1 |
18.0 - 20.1 |
22.5 - 25.4 |
12 |
1 |
22.8 - 25.4 |
28.6 - 31.8 |
20 |
1 |
28.8 - 31.6 |
35.2 - 39.0 |
27 |
1 |
32.8 - 36.0 |
39.5 - 44.0 |
37 |
1 |
38.5 - 42.3 |
45.7 - 50.4 |
|
No. of
Triples |
Nominal Conductor
Cross-Sectional
Area mm² |
Diameter over
inner sheath
min-max mm |
Diamètre de gaine
min-max mm |
Triples collective
|
3 |
0.75 |
14.2 - 16.2 |
18.3 - 20.7 |
7 |
0.75 |
19.4 - 21.9 |
24.0 - 27.0 |
12 |
0.75 |
24.2 - 26.8 |
29.3 - 32.9 |
3 |
1 |
15.1 - 17.1 |
19.4 - 22.2 |
7 |
1 |
20.9 - 23.4 |
25.6 - 28.7 |
12 |
1 |
25.8 - 28.5 |
31.8 - 35.5 |
Triples individual
|
1 |
0.75 |
7.7 - 9.4 |
11.5 - 13.3 |
3 |
0.75 |
14.2 - 16.2 |
18.6 - 20.9 |
7 |
0.75 |
19.7 - 22.1 |
24.4 - 27.4 |
12 |
0.75 |
24.4 - 27.1 |
30.4 - 34.1 |
1 |
1 |
8.4 - 10.1 |
12.1 - 14.0 |
3 |
1 |
15.0 - 17.2 |
19.4 - 22.3 |
7 |
1 |
21.0 - 23.5 |
25.7 - 28.8 |
12 |
1 |
26.2 - 28.9 |
32.2 - 36.0 |
|
|
|
|
|